Senec paint shop: blast cleaning and coating of steel components up to 26 m and 33 t
In Senec, on the D1 motorway, we blast-clean and spray-coat steel components up to 26 × 5 × 5 m and 33 t. The paint shop serves fabricators of steel structures, industrial buildings and containers that have no surface treatment facility of their own. The plant has a capacity of 750,000 m² of coatings per year.
We have been coating steel since 1991. The Senec plant has been in operation since 2023.
Dimensions and capacity
Plates and sections pass through the continuous blasting line. Welded assemblies and oversized parts are blast-cleaned and coated in an extracted booth. We receive components in the storage area and prepare them for dispatch after coating. On request, we can also store them here temporarily.


Surface preparation
Components are first degreased and then blast-cleaned with steel grit to preparation grade Sa 2½ in accordance with EN ISO 8501-1, or Sa 3 where required. The surface profile is assessed in accordance with EN ISO 8503. Areas that must not or cannot be blast-cleaned are cleaned by hand to grade St 3.
Compressed air for blasting and spraying is supplied by two Atlas Copco GA75L VSD+ FF compressors. On request, we carry out a Bresle test for soluble salts in accordance with ISO 8502-6 and ISO 8502-9 and a dust test in accordance with ISO 8502-3 before coating.



Coating application
Coatings are applied by airless spraying with Graco equipment. Edges, welds and openings are stripe-coated by brush before the full coat. Gaps in non-continuous welds are sealed before the topcoat.
For every coat we record air and substrate temperature, relative humidity and dew point. Dry film thickness (DFT) is measured in accordance with ISO 19840 and evaluated using the 80/20 rule.
Coating systems
We apply systems for corrosivity categories C3 to C5 in accordance with EN ISO 12944-2, including durability H (high) in accordance with EN ISO 12944-5. The system is selected according to your specification or according to the environment and the required durability.
| Corrosivity category | System | Total DFT | Indicative lead time |
|---|---|---|---|
| C3 | epoxy primer 80 µm + polyurethane topcoat 60 µm | 140 µm | 4 working days |
| C4 | epoxy primer 80 µm + epoxy intermediate coat 100 µm + polyurethane topcoat 60 µm | 240 µm | 5 working days |
| C5-H | zinc-rich epoxy primer 60 µm + 2 epoxy MIO intermediate coats, 180 µm in total + polyurethane topcoat 80 µm | 320 µm | 6 working days |
- Steel blast-cleaned to Sa 2½
- Surface profile Rz 50–75 µm (ISO 8503)
- Epoxy primer
- Zinc-rich epoxy primer
- Epoxy intermediate coat
- 2 epoxy MIO intermediate coats
- Polyurethane topcoat
- 4 working days
- 5 working days
- 6 working days
Layer thicknesses are shown to scale relative to each other.
Lead times apply from receipt of the components in Senec. We work with coating materials from:
- Jotun
- Hempel
- Sigma
- International
- Metrotect
- Copon
- Thortex
- JUB Kastaco
- Ameron
- Pyrostop
- Sika
FIRETEX FX6002 fire protection coatings are applied by us as an Approved Applicator of Sherwin-Williams.
Documentation with every order
With every delivery you receive an inspection record in Slovak and English. You can attach it to the documentation of your own production in accordance with EN 1090-2.
| Document | Standard | Scope |
|---|---|---|
| Surface cleanliness grade | EN ISO 8501-1 | every order |
| Surface profile | EN ISO 8503 | every order |
| Air and substrate temperature, humidity, dew point | – | every coat |
| Dry film thickness (DFT) | ISO 19840 | every coat |
| Coating batch numbers, technical and safety data sheets | – | every order |
| Cross-cut adhesion test (systems up to 250 µm) | EN ISO 2409 | on request |
| Pull-off adhesion test | EN ISO 4624, assessment to EN ISO 16276-1 | on request |
| Soluble salts (Bresle test) | ISO 8502-6, ISO 8502-9 | on request |
| Dust test | ISO 8502-3 | on request |
| Inspection report | FROSIO Level III inspector | on request |
Inspection is carried out by our own staff. Samuel Mikolajčík, our own employee, is a certified FROSIO Surface Treatment Inspector Level III (certificate no. 15629, valid until 16 October 2030). Our quality management system is certified to ISO 9001:2015.
Enquiries and quotations
We send a quotation within 5 working days on average. For an accurate price, please send us:
- drawings or a parts list
- weight in t and surface area in m²
- the coating system, or the corrosivity category and required durability
- the RAL colour of the topcoat
- planned delivery and collection dates
Location
The plant is located at Poľná 4, 903 01 Senec, Slovakia, on the former Montostroj site next to the D1 motorway.
| City | Road distance |
|---|---|
| Bratislava | 26 km |
| Vienna | 91 km |
| Brno | 138 km |
| Budapest | 182 km |
Senec lies directly on the D1 motorway
The paint shop sits at the centre of the motorway network between Vienna, Brno and Budapest. Road distances: Bratislava 26 km, Vienna 91 km, Brno 138 km, Budapest 182 km.
Illustrative map of the main motorways.
References
Technical containers
For the container manufacturers ZOVOS-EKO, KG-BAU, Constahl, Sekont, Rolfes and Technov we coat technical containers. Most of them serve as backup power units for data centres of global technology companies; others are used in mines, for biofilters, as ice-making containers or as battery storage units. In Senec and Tlmače we coat approximately 100 units per month, more than 1,200 per year. We have been coating them in Tlmače since 2008 and in Senec since 2023.
| Parameter | Value |
|---|---|
| Surface preparation | degreasing, blast cleaning to Sa 2½, internal surfaces St 3 |
| System | from C3 140 µm to C5-H 320 µm |
| Roofs | 240 µm system with anti-slip layer |


Fire protection coating, ESMC Dresden
In Senec we applied fire protection coating to the steel structures of the ESMC semiconductor plant in Dresden.
| Parameter | Value |
|---|---|
| Area | approx. 28,000 m² |
| Surface preparation | blast cleaning with GH40 steel grit, Sa 2½ |
| System | Macropoxy 400 primer 80 µm + FIRETEX FX6002 + Acrolon EG-5 topcoat |
| Average thickness | approx. 2 mm |
| Fire resistance | R90 |
| Period | 2025–2026 |

Contact
For enquiries or questions about coating systems, please contact the Senec plant directly.
General enquiries: +421 940 992 400, colorspol@colorspol.sk